These records explain internal quantity-conversion methods. User-entered consumption values must always be checked against the selected product’s current official datasheet.
alci-sivaMachine application takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Dynamic source based on product selection
- Formula version
- 3.0.1
- Validated inputs
- 12
Method record revision: 1 August 2026
alcipan-asma-tavanDrywall suspended ceiling system takeoff
Net ceiling area and perimeter are converted into boards, primary and secondary channels, hangers, anchors, clips, screws and jointing materials using the selected system spacing.
Framing, hanger spacing, ceiling drop and fixings must be verified against the current official system datasheet.
- Formula version
- 3.0.1
- Validated inputs
- 14
Method record revision: 1 August 2026
alcipan-bolme-duvarSystem-based wall takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
W11.tr · current official technical datasheet
- Formula version
- 3.0.1
- Validated inputs
- 16
Method record revision: 1 August 2026
astar-boyaProduct coverage, primer and coat-based paint takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Fenomastic Matt 13 m²/L/coat; Jotashield primer 12.7 m²/L/coat
- Formula version
- 3.0.1
- Validated inputs
- 12
Method record revision: 1 August 2026
betonConcrete geometric volume method
V = length × width × (thickness / 100) × element count
The tool only rounds geometric volume to the order increment; it does not design the concrete class or structural capacity.
- Formula version
- 3.0.1
- Validated inputs
- 8
Method record revision: 1 August 2026
bitumlu-membranOverlap, layer and upstand-based membrane takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Roll dimensions and overlaps are verified from the product label
- Formula version
- 3.0.1
- Validated inputs
- 14
Method record revision: 1 August 2026
boya-badanaRoom perimeter, height and ceiling-based paint takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Fenomastic Matt 13 m²/L/coat; Jotashield primer 12.7 m²/L/coat
- Formula version
- 3.0.1
- Validated inputs
- 14
Method record revision: 1 August 2026
cati-kiremitiRoof tile sloped-area method
Sloped area = plan area / cos(slope); field tiles = net sloped area × product consumption
Tiles/m², ridge and verge consumption values are entered from the selected Braas or Kılıçsan datasheet.
- Formula version
- 3.0.1
- Validated inputs
- 16
Method record revision: 1 August 2026
cati-panelEffective coverage and stock-length based takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Official product catalogue
- Formula version
- 3.0.1
- Validated inputs
- 13
Method record revision: 1 August 2026
cimentoCement dosage conversion method
Cement (kg) = application volume × approved cement dosage (kg/m³)
The dosage comes from the project specification; the tool does not create a mix design.
- Formula version
- 3.0.1
- Validated inputs
- 8
Method record revision: 1 August 2026
cleaneo-akustik-tavanD124 Cleaneo® perforated acoustic plasterboard ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
12.5 mm Cleaneo · official D124 system consumption rates
- Formula version
- 3.0.1
- Validated inputs
- 7
Method record revision: 1 August 2026
dekoratif-sivaDecorative facade render datasheet method
Product (kg) = net facade area × product consumption (kg/m²)
Grain structure, primer and consumption are taken from the selected topcoat datasheet.
- Formula version
- 3.0.1
- Validated inputs
- 12
Method record revision: 1 August 2026
derz-dolguTile geometry-based grout volume
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Official product document centre
- Formula version
- 3.0.1
- Validated inputs
- 9
Method record revision: 1 August 2026
duvar-blokAAC block, pallet and masonry adhesive takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Current dimensions, units/m² and pallet quantities
- Formula version
- 3.0.1
- Validated inputs
- 8
Method record revision: 1 August 2026
duvar-yapistiriciAdhesive takeoff by Ytong thickness and block type
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
15 kg of masonry adhesive per 1 m³ of Ytong blockwork
- Formula version
- 3.0.1
- Validated inputs
- 7
Method record revision: 1 August 2026
eps-yalitimEPS/ETICS component method
Each component = net facade area × selected system unit consumption
Package area, adhesive, base coat, dowel and mesh values must come from one approved system datasheet.
- Formula version
- 3.0.1
- Validated inputs
- 16
Method record revision: 1 August 2026
harcMortar project-mix method
Volume = area × thickness / 1000 + direct volume; component = volume × project dosage
Cement, lime and sand dosages are not proposed by the tool; the user enters them from the approved mix.
- Formula version
- 3.0.1
- Validated inputs
- 9
Method record revision: 1 August 2026
hazir-sivaReady-mix render datasheet method
Product (kg) = net area × thickness (mm) × product consumption (kg/m²/mm)
Corner profile, primer and consumption values are verified against the current system datasheet.
- Formula version
- 3.0.1
- Validated inputs
- 13
Method record revision: 1 August 2026
heradesign-tavanHERADESIGN® 600×600 / 600×1200 wood-wool ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
600×600 and 600×1200 modules · system-table values
- Formula version
- 3.0.1
- Validated inputs
- 7
Method record revision: 1 August 2026
insaat-demiriReinforcement weight method
Unit weight = d² / 162 kg/m; total weight = total length × unit weight
Diameter, count, net length and laps come from the approved structural design; the tool does not design reinforcement.
- Formula version
- 3.0.1
- Validated inputs
- 7
Method record revision: 1 August 2026
karolam-tavan60×60 Karolam modular ceiling · manufacturer-table modular ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
600×600 mm · 8 / 9,5 mm · 10 units/package
- Formula version
- 3.0.1
- Validated inputs
- 11
Method record revision: 1 August 2026
kendiliginden-sapSelf-levelling screed datasheet method
Product (kg) = net area × thickness (mm) × product consumption (kg/m²/mm)
Consumption and primer values must be entered from the current technical datasheet of the selected product.
- Formula version
- 3.0.1
- Validated inputs
- 11
Method record revision: 1 August 2026
kirecLime dosage conversion method
Lime (kg) = application volume × approved lime dosage (kg/m³)
The dosage comes from the project specification; the tool does not create a mix design.
- Formula version
- 3.0.1
- Validated inputs
- 8
Method record revision: 1 August 2026
lineer-metal-tavanLinear metal ceiling · centre- and module-based architectural ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Verify product dimensions and carrier spacing against the selected system datasheet.
- Formula version
- 3.0.1
- Validated inputs
- 8
Method record revision: 1 August 2026
mantolamaETICS project-datasheet method
Component requirement = net facade area × user-verified system consumption
No preset brand recipe is applied in generic project mode; all inputs must belong to the same ETICS system.
- Formula version
- 3.0.1
- Validated inputs
- 16
Method record revision: 1 August 2026
mesh-tavanExpanded-metal mesh ceiling · centre- and module-based architectural ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Module, cell and carrier dimensions vary by product range.
- Formula version
- 3.0.1
- Validated inputs
- 8
Method record revision: 1 August 2026
metal-baffle-tavanMetal baffle ceiling · centre- and module-based architectural ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Verify product dimensions and carrier spacing against the selected system datasheet.
- Formula version
- 3.0.1
- Validated inputs
- 8
Method record revision: 1 August 2026
metal-clip-in-3030×30 Clip-in concealed-grid metal ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
300×300 / 600×600 panels · verify omega-carrier and hanger spacing against the selected manufacturer datasheet
- Formula version
- 3.0.1
- Validated inputs
- 11
Method record revision: 1 August 2026
metal-clip-in-6060×60 Clip-in concealed-grid metal ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
300×300 / 600×600 panels · verify omega-carrier and hanger spacing against the selected manufacturer datasheet
- Formula version
- 3.0.1
- Validated inputs
- 11
Method record revision: 1 August 2026
metal-lay-in-6060×60 lay-in metal ceiling · manufacturer-table modular ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
12/2025 · 600×600 module: 0.84 m/m² main runner, 1.67 m/m² long cross tee, 0.84 m/m² short cross tee and 0.84 hangers/m²
- Formula version
- 3.0.1
- Validated inputs
- 11
Method record revision: 1 August 2026
metal-lay-on-6060×60 lay-on metal ceiling · manufacturer-table modular ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
12/2025 · 600×600 module: 0.84 m/m² main runner, 1.67 m/m² long cross tee, 0.84 m/m² short cross tee and 0.84 hangers/m²
- Formula version
- 3.0.1
- Validated inputs
- 11
Method record revision: 1 August 2026
mineral-baffle-tavanMineral baffle ceiling · centre- and module-based architectural ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Verify product dimensions and carrier spacing against the selected system datasheet.
- Formula version
- 3.0.1
- Validated inputs
- 8
Method record revision: 1 August 2026
mineral-yun-tavan60×60 mineral fibre acoustic ceiling · manufacturer-table modular ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
12/2025 · 600×600 module: 0.84 m/m² main runner, 1.67 m/m² long cross tee, 0.84 m/m² short cross tee and 0.84 hangers/m²
- Formula version
- 3.0.1
- Validated inputs
- 11
Method record revision: 1 August 2026
osb-duz-levhaEffective coverage and stock-length based takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Board dimensions depend on project/product selection
- Formula version
- 3.0.1
- Validated inputs
- 13
Method record revision: 1 August 2026
petek-tavanOpen-cell ceiling · centre- and module-based architectural ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Module, cell and carrier dimensions vary by product range.
- Formula version
- 3.0.1
- Validated inputs
- 8
Method record revision: 1 August 2026
seramik-karoTile layout method
Tile count = net area / single tile area; boxes and waste are rounded up for the selected layout
Tile dimensions and units per box are entered from the packaging; pattern and skirting are calculated separately.
- Formula version
- 3.0.1
- Validated inputs
- 10
Method record revision: 1 August 2026
seramik-yapistiriciTrowel and product consumption-based takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Official consumption table · 2025
- Formula version
- 3.0.1
- Validated inputs
- 13
Method record revision: 1 August 2026
silikon-mastikJoint cross-section and cartridge-volume based sealant takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Cartridge yield is calculated from joint width × depth
- Formula version
- 3.0.1
- Validated inputs
- 12
Method record revision: 1 August 2026
siva-alcisiManual application takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Dynamic source based on product selection
- Formula version
- 3.0.1
- Validated inputs
- 12
Method record revision: 1 August 2026
surme-su-yalitimiCoat, consumption and detail-tape based waterproofing takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Product datasheet consumption is verified by the user
- Formula version
- 3.0.1
- Validated inputs
- 17
Method record revision: 1 August 2026
t15-t24-tasiyiciT15/T24 exposed suspension grid · manufacturer-table modular ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
12/2025 · 600×600 module: 0.84 m/m² main runner, 1.67 m/m² long cross tee, 0.84 m/m² short cross tee and 0.84 hangers/m²
- Formula version
- 3.0.1
- Validated inputs
- 10
Method record revision: 1 August 2026
tasyunuSystem and package-based insulation takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Official technical guide · current package table
- Formula version
- 3.0.1
- Validated inputs
- 16
Method record revision: 1 August 2026
tasyunu-akustik-tavan60×60 stone wool acoustic ceiling · manufacturer-table modular ceiling takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
12/2025 · 600×600 module: 0.84 m/m² main runner, 1.67 m/m² long cross tee, 0.84 m/m² short cross tee and 0.84 hangers/m²
- Formula version
- 3.0.1
- Validated inputs
- 11
Method record revision: 1 August 2026
trapez-sacEffective coverage and stock-length based takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Official product catalogue
- Formula version
- 3.0.1
- Validated inputs
- 13
Method record revision: 1 August 2026
tugla-bimsPumice block size and pallet-based takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
G-series wall blocks · dimensions, units/m² and pallet quantities
- Formula version
- 3.0.1
- Validated inputs
- 7
Method record revision: 1 August 2026
xps-yalitimSystem and package-based insulation takeoff
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Official product technical datasheet
- Formula version
- 3.0.1
- Validated inputs
- 16
Method record revision: 1 August 2026
ytong-lentoOpening, bearing and quantity-based lintel preselection
Results are produced by combining project dimensions with packaging and consumption inputs entered across four calculation steps.
Lintel size calculation · maximum opening 500 cm
- Formula version
- 3.0.1
- Validated inputs
- 9
Method record revision: 1 August 2026
zemin-kaplamaFlooring package and layout method
Net area = length × width − openings; order = net area × (1 + layout and waste allowance)
Package coverage is entered from the product packaging; diagonal and patterned layouts add a cutting allowance.
- Formula version
- 3.0.1
- Validated inputs
- 11
Method record revision: 1 August 2026